COLD CONTROLS
TEMPORARY COLD CONTROL
REFRIG. OR FREEZER
CC1
Norm Norm
Warm
Cold
Cap
Part
Off
On
On
Off
Lgth.
No.
-11
3
-23
39
51" GC401
-11
3
-23
39
40" GC402
-11
3
-23
39
24" GC403
-5
12
-15
39
42" GC404
-4
10
-15
39
60" GC405
-1
15
-10
39
84" GC407
3
15
-7
39
33" GC406
12
24
-5
39
40" GC410
SPECIFICATIONS
CALIBRATION °F
UNIVERSAL REPLACEMENT
Norm Norm
Warm
Cold
Cap
Part
Off
On
On
Off
Lgth.
No.
-4
16
32
-23
24"
GC507
-1
13
29
-19
24"
GC509
5
29
42
-16
48"
GC504
9
20
38
-16
42"
GC501
9
26
42
-16
42"
GC503
18
31
48.5
-7
24"
GC506
31
36
49
16
24"
GC505
Norm
Norm Warm Cold
Cap
Part
Off
On
On
Off
Lgth.
No.
-10
4
18.5
-30
31"
GC608
-8
1
13
-23
31"
GC607
-7
4.5
19
-26
45"
GC610
-7
9
23
-26
24"
GC609
-5
15
27.5
-25
48"
GC606
-5
4
22
-29
78"
GC601
GC400 Series
The GC400 series are constant cut-in controls with
temperature ranges to meet current replacement
requirements. Constant cut-in at 39°F. Regardless
of dial setting, allowing automatic defrost with each
cycle. This keeps food within safe limits while
defrosting.
GC-500 Series
Constant differential controls maintain the same dif-
ference between on temperature and off tempera-
ture while control knob is moved from one setting to
another. A control with 10°F differential will main-
tain this difference from coldest to warmest setting.
The GC-500 series cold controls offer temperature
ranges and capillary lengths for replacement in
conventional "U" type evaporators through "frost-
less" models of refrigerators.
GC-600 Series
The GC-600 series cold control offer to the service
technician the temperature ranges and capillary
lengths for both "frostless" and conventional mod-
els of freezer and refrigerator design. You now
have a choice-choose the temperature range-
choose the capillary length to properly serve your
universal replacement demands.
SPECIFICATIONS
CALIBRATION °F
SPECIFICATIONS
CALIBRATION °F
Designed to service either refrigerators or
stand-alone freezers.
One unit for either application
Complete with Knob, Dial Plate, Mounting
Suction Cups and Terminals
Temperature adjustments can be made just as
with the original control
Will efficiently control temperature until exact
control is available
Specifications
Temporary Cold Control
Range = -5°F to +38°F
Cutout
Cutin
Cold
-5
+5
Normal
N/A
N/A
Warm
+32
+38
412
Part numbers and illustrations are for identification only
© 1971 - 2010 w.d. armstrong corp.